ISA-B2P

Soft Starter

8–58 A and 200–600 V


ISA-B2P Basic Soft Starter with built-in bypass

Advantages at a glance

  • Soft start and soft stop
  • Build-in bypass
  • Start/stop by dry contact
  • End of acceleration relay, NO contact
  • Compact, small foot print
  • DIN rail mounting (partly option)

Details

 

For full view please move the table horizontally if necessary.
Starter Type kW at 400 A Width (mm) Height (mm) Depth (mm) Weight (kg)
ISA-B2P 8 4 45 75 105 0.5
ISA-B2P 17 7.5 90 75 105 0.6
ISA-B2P 22 11 90 75 105 0.6
ISA-B2P 31 15 65 190 114 1.3
ISA-B2P 44 22 65 190 114 1.3
ISA-B2P 58 30 65 190 114 1.3

Approvals

Current limit

The voltage increases linearly from the “Initial Voltage“ pre selected point. If the adjusted “Current Limit” is reached, the voltage will stop ramping and remain at its level until the current is reduced below the adjusted “Current Limit“ level. In that case ramp up time is prolonged until the current has reduced below “Current Limit” level 

Soft starter output voltage

Although the current is limited the motor provides suitable torque to accelerate the driven load and reach “End of acceleration”. If the motor torque does not exceed the load torque the motor will not start. In the so rare cases severe damages might occur to the motor and starter.

Motor start measured with an oscilloscope
(Ch1, voltage; Ch2-4 current L1 – L3)

The oscillogram shows, the soft starter providing a smooth and stepless current and voltage ramp to the motor. The voltage ramps up until “Current Limit” is reached. After the motor is at nominal speed, the current will decrease, to the nominal motor current.

Pump control

Our digital Soft Starters line of products ISA-D, ISA-DS and ISA-HD provide an advanced microprocessor based control algorithm, enabling the sophisticated pump control feature. The motor torque is continuously monitored to eliminate peak
torque from stressing the motor, pump and pipe system. These soft starters provide 3 field selectable pump control algorithms.

Pump and special load control

Two major problems are associated with starting and stopping of pumps.

Over-pressure during starting

The sharp increase of torque towards the end of acceleration can cause high pressure and damage the pipe system. The pump control enables selection between three voltage ramp-up curves as well as torque curve to reduce peak torque. Current ramp is available for special loads.

Water hammer during stopping

During soft stop, when voltage is decreasing, motor torque may fall below load torque causing abrupt stalling instead of smoothly decreasing speed to zero. This creates the “water hammer” phenomenon (resulting in a loud noise and damage to the pipe system). The pump control algorithm enables selection between three voltage ramp-down curves or torque curve pre venting stall condition and eliminating water hammer.

Analogue

The analogue product line provides simple potentiometer settings for all the parameters:

  • Familiar setting, similar to standard overload relays
  • Easy commissioning
  • Prior knowledge is not necessary
  • Status display via LEDs

Communication RS 485

Modbus Profibus

RS 485 with MODBUS or PROFIBUS protocol enable:

  • Remote (start, stop, etc.)
  • Monitoring (motor current, faults, statistical data)
  • Remote parameter setting
  • Remote reset

Bypass

Internal bypass

  • This reliable components bypass the power electronics after the motor is at speed.
  • In addition the starters provide an auxiliary contact, allowing signaling of a successful motor start.
    Attention! Many of our competitors call these auxiliary relays “a bypass contact”!
  • The bypass function reduces the heat dissipation and eliminates the EMC load of the system.